1 范围 Scope
The purpose of this European Standard is to define requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically.
本欧洲标准的目的是对开闭电子控制的卫生龙头的标记、标识、密封性、电气和操作安全性以及机械阻力的要求进行定义。
The conditions of use for the supply system type are specified in Table 2:
供应系统类型的使用条件如表2所示:
Table 2 — Conditions of use
| 限制使用 | 限制使用 | 建议操作范围 | 建议操作范围 | ||
|---|---|---|---|---|---|
| 带有常开或常闭(单稳态)电磁阀的接头 | 带有锁存(双稳态)电磁阀的水龙头 | 带有常开或常闭(单稳态)电磁阀的接头 | 带有锁存(双稳态)电磁阀的水龙头 | ||
| 类型1 | 最小动态压力 | 0.05MPa(0.5bar) | 0.05MPa(0.5bar) | (0.1~0.5)MPa / (1-5)bar | (0.1~0.5)MPa / (1-5)bar |
| 类型1 | 最大静态压力 | 1MPa(10bar) | 1MPa(10bar) | 1MPa(10bar) | 0.8MPa(8bar) |
| 类型2 | 最小动态压力 | 0.01MPa(0.1bar) | 0.01MPa(0.1bar) | (0.01~0.2)MPa / (0.1-2)bar | (0.01~0.2)MPa / (0.1-2)bar |
| 类型1 | 最大静态压力 | 1MPa(10bar) | 1MPa(10bar) | 0.8MPa(8bar) | 0.6MPa(6bar) |
| 水温 | ≤75℃ | ≤75℃ | ≤6℃ | ≤65℃ |
For Type 2, the manufacturer is to declare the minimum operating pressure at which opening, closing and the specified flow rate can be obtained.
对于类型2,制造商应声明可获得开启、关闭和指定流量的最小工作压力。
There is usually no acoustic classification for tapware used in supply systems of Type 2 and no specifications governing the level of noise emissions from these water installations. If supply pressures are such that excessive noise is generated it is recommended that pressure or flow regulators are fitted in the system. Or where practicable, tapware conforming to the appropriate acoustic classification are used.
在2型供应系统中使用的标签件通常没有声学分类,也没有控制这些水设施的噪音排放水平的规范。如果供应压力产生过大的噪音,建议在系统中安装压力或流量调节器。或在切实可行的情况下,使用符合适当的声学分类的标记软件。
Annex B lists possible consequences of using a product outside its recommended operating range.
附件 B 列出了使用超出其他建议操作范围的产品的可能后果。
Annex B lists possible consequences of using a product outside its recommended operating range.

Key
1 cold water 冷水
2 hot water 热水
3 mains supply pipe (Supply pressures from (0,05 to 1,0) MPa ((0,5 - 10) bar) 主供水管道 (供应水压为0.5 bar-10 bar)
4 water heater 热水器
Figure 1 —Type 1 — Supply system with a pressure range of (0,05 to 1,0) MPa ((0,5 to 10) bar)
Key
1 cold water storage cistern 冷水水箱 (cover omitted for clarity 为了更直观,省略了上盖)
2 warning pipe 溢水管
3 vent pipe 排气管
4 hot water cylinder 热水箱
5 alternative cistern fed cold supply to sanitary appliances 卫生器具冷水供应备用水箱
6 to boiler 连接锅炉(boiler:烧水装置,家用热水器)
7 mains supply pipe主供水管道 (Supply pressures up to 8 bar 供应水压最高)
Figure 2 图2 — Type 2 — Supply system with a pressure range of (0,01 to 0,8) MPa ((0,1 to 8) bar) 供水压力范围为0.1bar-8 bar的供水系统
A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances.
设有排气管的家用热水及冷水供应系统,包括重力式热水、水管式冷水及可替代的重力式冷水供应卫生设备。